Product Description
ANALOG LOAD CELL
These load cells are manufactured using special alloy steel and high quality strain gauges. Temperature compensation is done for making these load cell operate over a wide temperature range.
FEATURES
- Current calibrated for precision output
- Higher Accuracy
- Minimal corner error
- Cup ball mechanism for very easy installation & maintenance
- Easy field replaceability
- Cost Effective
- Galvanized Bottom: This prevents Rusting of Body and gives a cleaner look
- Modified Looks: The load cells are given a different finish and they appear cleaner in looks compared to other load cells
- Special Cable: High strength cable with better finish is provided to give more strength and better noise immunity
- Strong Technical Support: APPALTO is a reputed brand in the Indian weighing industry for more than 25 Years. Appalto load cells are supported by strong technical team for any field or design related issues
- Warranty: These load cells carry a warranty of twelve months from the date of dispatch against any manufacturing defect against any manufacturing defect
TECHNICAL SPECIFICATIONS
| SENSITIVITY | | 2.00 0.002 mV/V |
| ERROR CLASS | | C2 |
| CREEP (30 MINUTES) | | 0.02%FS |
| ZERO BALANCE | | 1%FS |
| TC ZERO | | 0.02%FS/10 C |
| TC SPAN | | 0.02%FS/10 C |
| INPUT RESISTANCE | | 75010 |
| OUTPUT RESISTANCE | | 7503 |
| INSULATION RESISTANCE | | 5000M |
| MAXIMUM SAFE OVER LOAD | | 150%FS |
| ULTIMATE OVER LOAD | | 300%FS |
| EXCITATION RECOMMENDED | | 10~12V DC |
| EXCITATION MAXIMUM | | 15V DC |
| PROTECTION CLASS | | IP68 |
| CONSTRUCTION | | ALLOY STEEL |
| CABLE LENGTH | | 12 M |
Precision Engineering for Industrial ApplicationsBuilt from alloy steel and hermetically sealed, this analog load cell delivers reliable, repeatable measurements even in challenging environments. Its robust construction ensures stability and a long lifespan, making it suitable for a range of industrial weighing systems. The bolt-fixed mounting and metallic grey finish are tailored for easy integration with platform and hopper scales.
Superior Sensitivity and AccuracyWith an output sensitivity of 2.0 mV/V and accuracy rated at 0.02% F.S., this load cell meets stringent demands for precision. Whether you require exact force measurement or consistent weight assessments, its advanced design minimizes errors, guaranteeing precise readings in every operation. The analog meter display aids straightforward interpretation, supporting operational efficiency.
Reliable Operation Across Diverse ConditionsWith an operating temperature range from -10C to +50C and IP67-rated protection, the load cell is engineered to withstand moisture, dust, and temperature fluctuations. The device preserves accuracy and stability, making it ideal for indoor and outdoor installations. Its internationally recognized ISO 9001:2015 certification underscores its quality and reliability.
FAQs of ANALOG LOAD CELL:
Q: How do I install the analog load cell on my industrial weighing platform?
A: Installation involves bolt-fixed mounting, using the provided mounting points to securely attach the load cell to your scale structure. Ensure cable terminals are properly connected to your analog meter or monitoring system, and verify electrical connections match the excitation voltage requirements (512 VDC).
Q: What are the main benefits of using this analog load cell for weight measurement?
A: This load cell offers high stability, robust construction, and a hermetically sealed, IP67-rated design for reliable performance in industrial environments. Its superior sensitivity and accuracy (0.02% F.S.) make it ideal for precise force and weight measurements across a range of applications.
Q: Where can this load cell be applied effectively?
A: The analog load cell is widely suited for hopper scales, platform scales, and other industrial weighing applications where accurate load measurement and robust operation are necessary. Its metallic grey, compact build integrates seamlessly into many industrial setups.
Q: What process should I follow to ensure accurate readings from the load cell?
A: Ensure the load cell is properly bolted and aligned, cables are connected to a calibrated analog meter, and the excitation voltage (512 VDC) is within specification. Periodic calibration and keeping the load cell free from excessive shock or overload beyond 150% of full scale maintain reliable performance.
Q: When should I use an analog load cell over a digital one?
A: Analog load cells are ideal when you require simple, robust weight measurement with direct analog meter display, or where legacy systems dominate. Their passive power operation and straightforward wired connectivity make them practical for industries prioritizing reliability and ease of maintenance.
Q: What kind of maintenance does this load cell require?
A: Maintenance includes regular inspection for physical damage, ensuring cable terminals remain free from corrosion, and periodic calibration checks to sustain high accuracy. Its hermetically sealed and IP67-rated enclosure minimizes internal contamination and reduces overall maintenance frequency.
Q: How does the load cell handle harsh environments or exposure to moisture?
A: Thanks to its hermetically sealed construction and IP67 rating, the load cell resists ingress of dust and moisture, allowing consistent operation in demanding conditions. Combined with a wide operating temperature range, it offers stable performance for both indoor and outdoor industrial weighing tasks.